Tuesday 23 August 2011

Remote Access for SL1000

The SL1000 system allows remote access for engineers to perform their maintenance tasks, MACD tasks, etc.

Below shows you what is required in terms of hardware / setup;


  • Hardware: PZ-VM21 mounted on CPU card
  • Setup procedures, see below;


STEP 1:

For PZ-VM21 the modem related setting will be as below:



(for Analog CO trunk)



               PRG11-15-14 746 (assign any unique service code) – please check your numbering plan, have to be unique code in the system

PRG22-02-01 assigns Trunk to “DIL”

PRG22-07-01 set DIL destination “746”



(for ISDN trunk)



               PRG11-15-14 746 (assign any unique service code) - – please check your numbering plan, have to be unique code in the system

PRG22-02-01 assigns Trunk to “DID”

PRG22-11-01 map external ISDN DDI number to internal , in this case ‘746’





STEP 2:

Refer to attached http://www.mediafire.com/?bnx3ki4s9kjzdwk